- ThermOmegaTech’s Thermal Bypass Valve with Pressure Relief combines two essential functions into one component. Equipped with a thermal actuator, the valve will modulate open and closed based on temperature changes.
- The built-in pressure relief safeguards the system from excessive pressure buildup. If the pressure exceeds a predetermined threshold, the relief valve opens, allowing fluid to escape and reducing pressure to a safe level.
- The TBV-PR can be integrated into a 4-way manifold to monitor and divert fluid based on temperature. Cooler fluid goes through the valve bypass, while hotter fluid goes through the system’s cooler.
- Exclusive Thermoloid® thermal actuator
- Integrated pressure relief
- Standard valve material is brass or stainless steel
- Reactive, compact, and low mass – fast response
- Corrosion-resistant, long service life
- Cooling Water Control for Radiator or Heat Exchanger
- Electronics System Cooling
- Engine and Compressor Cooling System
- Hydraulic Fluid or Lube Oil Cooling Systems
- Hydraulic Power Units (HPUs)
- Hydraulic or Lube Oil Thermal Bypass
- Loop-type Circulation Systems
- Self-operating – no external power source required
- Temperature control – controls fluids by sensing over-temperature thermal levels
- Built-in pressure relief simplifies installation and maintenance processes
- Wide temperature range available
- Minimal maintenance needed
- Few moving parts – reduce system wear
| Series | TBV-PR |
| Description | SAE-18-TBV-PR-XXX-S6-B-XXX |
| Diameter-in | 4.8 |
| Diameter-mm | 122 |
| Weight lb | 1.3 |
| Weight kg | 0.6 |
| Cv | 12.6 |
| Maximum Operating Pressure | 440 PSI (30.3 BAR) |
| Maximum Temperature | 150ºF (66ºC) over set-point limit 250ºF (149ºC) |
| L Closed in | 2.337 |
| L Closed mm | 59.4 |
| Isometric View | Download |
| Front View | Download |
| Top View | Download |
| Side View | Download |
Disclaimer
All drawings and 3D models are provided for reference only and are not controlled documents. Files may not reflect current revisions or design intent and shall not be used for manufacturing, inspection, or certification. Only officially released ThermOmegaTech drawings and documents issued through the company’s controlled document system are considered authoritative.
All drawings and 3D models are provided for reference only and are not controlled documents. Files may not reflect current revisions or design intent and shall not be used for manufacturing, inspection, or certification. Only officially released ThermOmegaTech drawings and documents issued through the company’s controlled document system are considered authoritative.